Yalun WuABSTRACT
The reliability of distribution network is an important index to ensure high-quality power supply. In this paper, the FMEA table is established based on the traditional power supply mode consequence analysis method, and the network topology after power supply isolation is determined by querying the table according to the power supply information. Then, the control mode of VSC is adjusted according to the VSC control strategy under different power supply conditions. Finally, through network reconfiguration and island operation, the continuous spatiotemporal power grid topology power supply restoration optimization model is established. On this basis, this paper combines sequential Monte Carlo method to evaluate the reliability of continuous spatiotemporal power grid topology, and illustrates the reliability evaluation difference caused by the difference of distribution network topology information.
KEYWORDS
Sequential Monte Carlo method, Continuous spatiotemporal power grid topologyCITE THIS PAPER
Yalun Wu, Shuai Jing, Zheren Li, Lingwei Xu, Ruilin Liu, Zhixin Qu. Research on Distribution Network Reliability and Power Supply Soft Self-healing. Smart Systems and Green Energy (2021) Vol. 3: 30-35. DOI: http://dx.doi.org/10.23977/ssge.2021.030106.
REFERENCES
[1] Sun Yuanyuan, Zhang Wenjun, Shan Hongtao, Chen chuanjuan, Duan Chuanke. Reliability analysis of distribution network based on DBN [J]. Manufacturing automation, 2021, 43 (07): 64-67 + 86
[2] Zhang Lu, Yu Shunjiang, Wang Chen, Tang Wei, Zhang Xiaohui. Reliability evaluation of AC / DC hybrid distribution network considering VSC operation mode and fault recovery optimization [J / OL]. Power grid technology: 1-13 [2021-08-10] https://doi.org/10.13335/j.1000-3673.pst.2021.0169.
[3] Liu Liyang, Li Xin, Zhang Wentao, Wei Jun, ye Shengyong. Severity analysis and reliability evaluation of power outage perceived by distribution network users [J]. Sichuan electric power technology, 2021, 44 (03): 61-68.
[4] Zhou Dandan. Automatic judgment, estimation and control of line faults in complex dynamic networks [D]. Huazhong University of science and technology, 2019.