Education, Science, Technology, Innovation and Life
Open Access
Sign In

Comparison and Analysis of Dynamic Stiffness Tests of Natural Foundation and Pile Foundation under Forced Vibration

Download as PDF

DOI: 10.23977/jemm.2022.070406 | Downloads: 20 | Views: 468

Author(s)

Zizhen Shen 1, Weiding Chen 1

Affiliation(s)

1 Zhejiang College of Construction, Hangzhou, 311215, China

Corresponding Author

Zizhen Shen

ABSTRACT

The dynamic stiffness test of foundation and pile foundation is also aimed to provide dynamic design parameters of some important equipment foundation under vibration load.Through the dynamic stiffness test of foundation and pile foundation, the working performance of foundation and pile foundation under vibration load is understood, and the necessary dynamic design parameters of foundation and pile foundation are provided. According to the characteristics of continuous or intermittent vibration of soil and pile foundation, the vibration tests of natural foundation and pile foundation are carried out to measure the compressive stiffness, shear stiffness, bending stiffness coefficient, axial vibration damping ratio and horizontal and rotary coupling vibration damping ratio of natural foundation and pile foundation.Combined with the engineering characteristics of the gas-steam combined cycle power station, the gas turbine is a periodic vibration device. Therefore, this paper mainly studies the comparison and analysis of the dynamic stiffness test of natural ground foundation and pile foundation in forced vibration test.

KEYWORDS

Forced vibration, Pile foundation, Dynamic stiffness, Compressive stiffness, Shear stiffness, Flexural stiffness coefficient

CITE THIS PAPER

Zizhen Shen, Weiding Chen, Comparison and Analysis of Dynamic Stiffness Tests of Natural Foundation and Pile Foundation under Forced Vibration. Journal of Engineering Mechanics and Machinery (2022) Vol. 7: 53-67. DOI: http://dx.doi.org/10.23977/jemm.2022.070406.

REFERENCES

[1] Wang L, Lv JQ, Zhu WJ & Zheng S M. (2011). Measurement and analysis of forced vibration of natural foundation.Geodesy and geodynamics (02) 84-88. 
[2] The National Standards Compilation Group of People's Republic of China. Measurement method of dynamic properties of subsoil(GB/T50269-2015)[S]. Beijing:China Architecture and Construction Press,2015 Building Press,2015)
[3] Zhi, L.Y. & Zhi, L.Y. (2018). Experimental study of different types of vibration shakers in ground dynamic testing.Construction Technology (S4),18-21.
[4]  Sun, Y.L., Sun, G.J., & Huang, Q. (2014). Research on vertical forced vibration of natural foundation: A case study of vibration test engineering.Journal of Changchun Institute of Technology (Natural Science Edition)(01),13-17.
[5]   Liang Feng. (2009). The flow pipe transverse vibration mechanism and control research (Ph.D. Dissertation, Northeastern University).https://kns.cnki.net/KCMS/detail/detail.aspx?dbname=CDFD0911&filename =2010055585. nh
[6] Ge, L., Shen, H., Lin, Z., (2002). Forced vibration of symmetrically cross-laid laminated plates on elastic foundation.Journal of Shanghai jiaotong university (11), 1634-1639 + 1648. 
[7] Song L & Zhang J Y. (1997). Solution to the problem of circular thin plate vibration on elastic foundation.Metal Forming Technology (04),34-38+56. Doi.
[8] Liang Fayun,Li Tongda,Qian Yu,Wang Chen & Jia Yajie.(2021).Investigating the seismic isolation effect of the cushioned pile raft foundation in soft clay through dynamic centrifuge tests. Soil Dynamics and Earthquake Engineering. 
[9] Gui Lin Sheng,,Cai Li Su & De Hui Liu.(2013).Analysis of Dynamic Performance of Rigid Pile Composite Foundation. Applied Mechanics and Materials.

All published work is licensed under a Creative Commons Attribution 4.0 International License.

Copyright © 2016 - 2031 Clausius Scientific Press Inc. All Rights Reserved.